Fire Duct Door & Fire Shaft Door Manufacturer in Pune, Maharashtra

Fire incidents in commercial and industrial buildings often start or spread silently through HVAC ducts and vertical shafts. Flames and smoke can move rapidly, putting lives, property, and compliance at risk. Without proper fire-rated protection, even a small fire can escalate into a major disaster.

Duct Doors & Fire Shaft Door Solutions

Our duct doors are designed to provide easy and secure access to duct systems for maintenance and inspection. Built with high-quality materials, these doors ensure durability and safety in industrial environments. We also offer fire shaft door solutions that are suitable for vertical shafts and service areas, helping maintain safety compliance while supporting efficient building operations.

At MPS Techno Fab, we are a trusted Fire Duct Door Manufacturer in Pune and across Maharashtra. Our doors comply with NBC 2016 and IS 3614 standards, offering up to 120-minute fire resistance to safeguard your building, occupants, and infrastructure.

We address real-world challenges like smoke leakage, fire spread, and maintenance hurdles while ensuring regulatory compliance. Whether it’s a high-rise commercial complex, hospital, industrial plant, or IT park, our fire-rated solutions combine durability, precision engineering, and local expertise.

What Are Fire Duct & Fire Shaft Doors

Fire Duct Door: A fire-rated panel installed on HVAC ducts to prevent flames and smoke from spreading while providing maintenance and inspection access.

Fire Shaft Door: Heavy-duty doors installed in vertical shafts, such as lift shafts, electrical shafts, or utility shafts, preventing fire from spreading between floors.

These doors are a critical part of passive fire protection systems, containing fire within designated areas and protecting evacuation routes.

How They Work

Features & Technical Specifications

Features & Benefits:

Fire Resistance (60/90/120 min): Maximum protection and NBC compliance.
Smoke-Proof Sealing: Prevents hazardous smoke from entering occupied areas.
Intumescent Seals: Expand under heat to close gaps and stop fire spread.
Heavy-Duty Construction: Durable steel for long-term performance.
Corrosion Resistance: Protects against moisture, reducing maintenance.
Easy Maintenance: Quick-access panels for inspection and cleaning.
Custom Sizes: Tailored for any duct or shaft dimensions.
Certified Materials: NBC 2016, IS 3614, ISO-approved materials ensure reliability.

Technical Specifications Table

Specification Details
Material Cold-rolled steel / Galvanized steel
Thickness 1.2 mm – 2.0 mm
Fire Rating upto 120 minutes
Insulation Rockwool or ceramic fiber
Sealing Intumescent & smoke-proof seals
Hardware Stainless steel hinges, locks, handles
Finish Powder-coated / Epoxy paint
Compliance NBC 2016, IS 3614, ISO-certified materials

Recommended Hardware

Fire Rated Butt Hinges (ISI Marked)
Self-Closing Mechanism / Door Closer
Fire Resistant Locking System
D-Type / Panic Bar Handle
Holdfasts / Dash Fasteners

Performance & Efficiency Benefits

  • Rapid containment of fire and smoke
  • Reduces risk of structural damage
  • Minimizes downtime during maintenance or fire incidents
  • Long-lasting materials ensure reduced replacement costs
  • Optimized design for HVAC airflow and access efficiency

Fire Safety & Compliance

  • Fully NBC 2016 compliant
  • Meets IS 3614 fire door standards
  • ISO-certified materials for durability and performance
  • Intumescent and smoke-proof sealing ensure real-world fire protection

Applications

  • Commercial Buildings: Offices, malls, hotels
  • Hospitals: Protects patients and emergency evacuation routes
  • Industrial Plants: Safeguards production and storage zones
  • HVAC Systems: Fire containment within ventilation ducts
  • High-Rise Buildings: Prevents vertical fire spread via shafts
  • IT Parks & Malls: Ensures safety for employees, visitors, and equipment

Industries We Serve

  • IT Parks & Commercial Complexes
  • Healthcare & Hospitals
  • Hospitality & Hotels
  • Retail Malls & Shopping Centers
  • High-Rise Residential & Office Buildings

Installation Process

  • Pre-installation inspection and measurement
  • Custom fabrication for duct/shaft dimensions
  • Professional installation by certified engineers
  • Testing and commissioning for fire compliance
  • Handover with maintenance and safety guidelines

Quality & Manufacturing Assurance

  • In-house manufacturing ensures full quality control
  • Use of certified, durable steel and insulation materials
  • Compliance with NBC 2016 & IS 3614 standards
  • Long-term warranty and maintenance support

Product Customization & Why Choose Us

Product Customization Options

  • Custom sizes for any duct or shaft dimension
  • Powder-coated finishes for aesthetics and corrosion resistance
  • Optional hardware upgrades for industrial or high-security applications
  • Specialized sealing for high-temperature or high-humidity environments

Why Choose MPS Techno Fab

  • Experience & Expertise: Decades of manufacturing fire-rated doors
  • In-House Manufacturing: Complete quality control and customization
  • Custom Solutions: Fit doors to any duct or shaft size
  • Timely Delivery: Serving Pune & Maharashtra reliably
  • Certified Materials: NBC 2016 & IS 3614 compliant, ISO-approved
  • Expert Team: Engineers ensure optimal design
  • Trusted by Professionals: Used in IT parks, hospitals, high-rise buildings

Fire Duct Door vs Fire Shaft Door: Key Differences

Feature / Aspect Fire Duct Door Fire Shaft Door
Primary Function Prevents fire and smoke from spreading through HVAC ducts Prevents vertical fire spread through lift, electrical, or utility shafts
Placement Horizontal duct openings Vertical shafts between floors
Fire Rating 60 / 90 / 120 minutes 60 / 90 / 120 minutes
Sealing Type Intumescent + smoke-proof seals Intumescent + smoke-proof seals
Access Maintenance/inspection for ducts Maintenance access for shaft equipment
Applications HVAC systems, commercial buildings, hospitals, IT parks High-rise buildings, lift shafts, electrical shafts, industrial plants
Design Compact, panel-type, integrated with ducts Heavy-duty, full door, designed for vertical shafts
Compliance NBC 2016, IS 3614 NBC 2016, IS 3614

Summary: Fire Duct Doors control horizontal fire spread, while Fire Shaft Doors manage vertical fire containment. Both are essential for passive fire protection.